Using colloidal gold immunochromatographic assay (GICA) technology, our strips deliver rapid, visual results with minimal sample prep — perfect for daily dairy quality control.
Routine screening is a critical checkpoint across the dairy supply chain — from raw milk collection to finished product manufacturing — helping catch potential contamination before it reaches the next stage of processing.
Rapid tests don’t replace laboratory confirmation. They provide an efficient first-line screening tool that helps quality control teams make faster decisions, avoid unnecessary processing costs, and support broader food safety management systems.
Screen incoming milk before storage, transportation, or production.
Results in approximately 10 minutes, so QC personnel can respond quickly to potential contamination.
Minimal sample preparation — no complex laboratory operations required.
Fits directly into internal QA procedures and food safety management systems.

Technical Statement: Rapid test strips are intended for preliminary screening. When required by regulatory authorities or QMS procedures, positive or suspicious results should be confirmed using appropriate reference analytical methods.
Finder Bio milk rapid test strips support routine quality screening at every stage of the dairy supply chain and across the wider food safety ecosystem — from farm-level testing to regulatory monitoring.

Routine screening of raw milk before transport, storage, or sale.

Monitor raw materials and production batches throughout manufacturing.

Rapid preliminary screening ahead of confirmatory laboratory analysis.

Support food safety surveillance and routine regulatory monitoring.
Finder Bio offers a complete portfolio of milk rapid test strips covering mycotoxin and antibiotic residue screening. Compare products below to find the right fit for your target analyte and testing requirements.

Catalog No.:S004601
Target:Aflatoxin M1
Detection Limit:0.5 ppb
Sample Type:Milk
Method:GICA
Result Time:Approx. 10 min

Catalog No.:S101601
Target:Chloramphenicol
Detection Limit:0.3 ppb
Sample Type:Milk
Method:GICA
Result Time:Approx. 10 min

Catalog No.:S102601
Target:Tetracyclines
Detection Limit:Refer to IFU
Sample Type:Milk
Method:GICA
Result Time:Approx. 10 min

Catalog No.:S110601
Target:Quinolones
Detection Limit:10.0 ppb
Sample Type:Milk
Method:GICA
Result Time:Approx. 10 min

Catalog No.:S126604
Target:Beta-lactams
Detection Limit:Refer to IFU
Sample Type:Milk
Method:GICA
Result Time:Approx. 10 min

Catalog No.:S126602
Target:Beta-lactams, Tetracyclines
Detection Limit:0.5 ppb
Sample Type:Milk
Method:GICA
Result Time:Approx. 10 min

Catalog No.:S126603
Target:Beta-lactams, Sulfonamides, Tetracyclines
Detection Limit:Refer to IFU
Sample Type:Milk
Method:GICA
Result Time:Approx. 10 min

Catalog No.:S126601
Target:Beta-lactams, Ceftiofur, Tetracyclines, Chloramphenicol
Detection Limit:Refer to IFU
Sample Type:Milk
Method:GICA
Result Time:Approx. 10 min

Catalog No.:S126605
Target:Beta-lactams, Ceftiofur, Tetracyclines, Sulfonamides
Detection Limit:Refer to IFU
Sample Type:Milk
Method:GICA
Result Time:Approx. 10 min
Need help selecting? Our technical team can recommend the right product based on your target analyte, sample type, and testing requirements.
Finder Bio rapid test strips use Colloidal Gold Immunochromatographic Assay (GICA) — a well-established method for rapid food safety screening. The target analyte competes with an immobilized antigen for gold-labeled antibodies; results are read visually via the Test Line (T) and Control Line (C), with no specialized laboratory equipment required.

Collect and prepare the milk sample per product instructions.

Transfer the required sample volume into the reaction microwell or tube.

Mix thoroughly and allow the specified incubation time.

Insert the test strip and allow chromatographic migration.

Interpret within the specified reading time using the T/C lines. Results outside the recommended window are not valid.
Negative — Test Line equal to or darker than Control Line: analyte below detection limit.
Positive — Test Line lighter than Control Line or absent: analyte at/above detection limit; confirm with a reference method if required.
Invalid — Control Line does not appear: repeat with a new device and fresh sample.
As a direct manufacturer, Finder Bio integrates product development, production, and quality control under one system — giving distributors, laboratories, and OEM partners consistent product quality and responsive support for long-term cooperation.
Full control from R&D to QC, ensuring consistent batch-to-batch quality.
CE, ISO 9001, and GMP certified manufacturing.
Private labeling, custom packaging, and distributor branding, with multilingual documentation support.
Stable supply, training, and after-sales support for long-term regional distributor partnerships worldwide.
Whether you’re sourcing routine milk rapid test strips, evaluating OEM opportunities, or expanding your distribution portfolio, our team is ready to assist with product selection and technical support.
Contact us to discuss your application requirements and receive detailed product information.
Copyright © 2026 Shenzhen Finder Biotech Co., Ltd.
Main Site