FinderBio Mycotoxin Fluorescence Detection Solution

Table of Contents
Features
High sensitivity and specificity
Capable of detecting trace concentrations of target molecules, suitable for trace-level analysis.
Real-time quantification
Fluorescence signals are recorded synchronously during detection, avoiding endpoint analysis errors.
Standardized process
Unified sample pretreatment and testing procedures minimize human error and ensure result consistency.
Multi-analyte compatibility
Supports detection of various mycotoxins, including aflatoxins, deoxynivalenol (DON), ochratoxin A (OTA), and zearalenone (ZEN).
Rapid and efficient
Each test takes only 15–30 minutes, ideal for both field and laboratory applications.
Intelligent interpretation
The fluorescence strip reader automatically recognizes the test card and outputs data, providing intuitive, accurate, and traceable results.
Detection Principle
The system is based on fluorescence immunochromatography, which enables quantitative detection through the specific interaction between antigens and antibodies. The target mycotoxin in the sample first binds to the fluorescently labeled specific antibody to form an immune complex. As the complex migrates along the strip, it reaches the test line where it competes with the immobilized antigen for binding sites. This competitive reaction generates a fluorescence signal that is inversely proportional to the toxin concentration.
The fluorescence reader then measures the signal intensity on the test strip and calculates the actual mycotoxin concentration in the sample according to the standard curve, enabling highly sensitive, rapid, and quantitative analysis.

Performance Index
Detection Time: Approximately 10–15 minutes
Detection Sensitivity: At the ng/mL level
Accuracy: High consistency with HPLC results

Detection Workflow

Analytes Tested
| Test Item | Detection Range | Sample |
|---|---|---|
| Deoxynivalenol (DON) | 100–10000 μg/kg | Feed,corn,and wheat |
| Aflatoxin B1 (AFB1) | 1–100 μg/kg | Grain, feed, peanut |
| Total Aflatoxins (AFT) | 1–100 μg/kg | Grains and oilseeds |
| Zearalenone (ZEN) | 10–1000 μg/kg | Feed, corn |
| Aflatoxin M1 (AFM1) | 0.05–1 μg/kg | Milk |
| T-2 Toxin (T2) | 10–1000 μg/kg | Feed, wheat |
| Ochratoxin A (OTA) | 1–200 μg/kg | Grain, feed,coffee |
| Fumonisin (FUM) | 50–5000 μg/kg | Corn, feed |
Required Instruments
The instruments ensure standardized, reproducible testing for both lab and on-site use.

Fluorescence Strip Reader
A high-sensitivity instrument that rapidly reads fluorescence signals and quantitatively analyzes mycotoxin levels in samples.

Handheld Fluorescence Strip Reader
Portable fluorescence reader, compact and easy to carry.

Thermo Incubator
Provides a constant temperature environment to ensure uniform and stable reactions between samples and reagents.

Grinder
Efficiently grinds solid feed or grains into uniform particles for easier extraction and analysis.

Electronic scale
Accurately weigh the required sample, precise to 0.01g

Vortex Mixe
Quickly mixes liquid samples and reagents to enhance reaction uniformity.

Mini Centrifuge
Compact and portable, rapidly separates liquids and sediments to improve testing efficiency.

Pipette Set
Accurately transfers small volumes of samples and reagents, ensuring precise and reliable experimental operation.

Experimental consumables
Provide a certain amount of experimental consumables
Operation video
Related products







